Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biomed Pharmacother ; 168: 115702, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37837879

RESUMO

Intimal hyperplasia (IH) is a major cause of vascular restenosis after bypass surgery, which progresses as a series of processes from the acute to chronic stage in response to endothelial damage during bypass grafting. A strategic localized drug delivery system that reflects the pathophysiology of IH and minimizes systemic side effects is necessary. In this study, the sequential release of sirolimus, a mechanistic target of rapamycin (mTOR) inhibitor, and statin, an HMG-COA inhibitor, was realized as a silk fibroin-based microneedle device in vivo. The released sirolimus in the acute stage reduced neointima (NI) and vascular fibrosis through mTOR inhibition. Furthermore, rosuvastatin, which was continuously released from the acute to chronic stage, reduced vascular stiffness and apoptosis through the inactivation of Yes-associated protein (YAP). The sequential release of sirolimus and rosuvastatin confirmed the synergistic treatment effects on vascular inflammation, VSMC proliferation, and ECM degradation remodeling through the inhibition of transforming growth factor (TGF)-beta/NF-κB pathway. These results demonstrate the therapeutic effect on preventing restenosis with sufficient vascular elasticity and significantly reduced IH in response to endothelial damage. Therefore, this study suggests a promising strategy for treating coronary artery disease through localized drug delivery of customized drug combinations.


Assuntos
Fibroínas , Sirolimo , Animais , Humanos , Sirolimo/farmacologia , Rosuvastatina Cálcica/farmacologia , Hiperplasia , Proliferação de Células , Modelos Animais de Doenças , Serina-Treonina Quinases TOR
2.
Nat Commun ; 14(1): 6768, 2023 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-37880242

RESUMO

Interest in securing energy production channels from renewable sources is higher than ever due to the daily observation of the impacts of climate change. A key renewable energy harvesting strategy achieving carbon neutral cycles is artificial photosynthesis. Solar-to-fuel routes thus far relied on elaborately crafted semiconductors, undermining the cost-efficiency of the system. Furthermore, fuels produced required separation prior to utilization. As an artificial photosynthesis design, here we demonstrate the conversion of swimming green algae into photovoltaic power stations. The engineered algae exhibit bioelectrogenesis, en route to energy storage in hydrogen. Notably, fuel formation requires no additives or external bias other than CO2 and sunlight. The cellular power stations autoregulate the oxygen level during artificial photosynthesis, granting immediate utility of the photosynthetic hydrogen without separation. The fuel production scales linearly with the reactor volume, which is a necessary trait for contributing to the large-scale renewable energy portfolio.

3.
ACS Appl Mater Interfaces ; 15(14): 17653-17663, 2023 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-37010291

RESUMO

Atherosclerosis is one of the severe cardiovascular diseases in which blood vessels lose elasticity and the lumen narrows. If atherosclerosis worsens, it commonly leads to acute coronary syndrome (ACS) due to the rupture of vulnerable plaque or aortic aneurysm. As the mechanical properties of vascular tissues vary from their conditions, measuring the vascular stiffness of an inner blood vessel wall may be applied to the accurate diagnosis of atherosclerotic symptoms. Therefore, early mechanical detection of vascular stiffness is highly needed for immediate medical attention for ACS. Even with conventional examination methods such as intravascular ultrasonography and optical coherence tomography, several limitations still remain that make it difficult to directly determine the mechanical properties of the vascular tissue. As piezoelectric materials convert mechanical energy to electricity without an external power source, a piezoelectric nanocomposite could be utilized as a balloon catheter-integrated mechanical sensor on its surface. Here, we present piezoelectric nanocomposite micropyramid balloon catheter (p-MPB) arrays for measuring vascular stiffness. We study the structural characterization and feasibility of p-MPB as endovascular sensors by conducting finite element method analyses. Also, multifaceted piezoelectric voltages are measured by compression/release tests, in vitro vascular phantom tests, and ex vivo porcine heart tests to confirm that the p-MPB sensor properly operates in blood vessels.


Assuntos
Aterosclerose , Placa Aterosclerótica , Rigidez Vascular , Animais , Suínos , Ultrassonografia de Intervenção/métodos , Cateteres Urinários
4.
Int J Mol Sci ; 24(4)2023 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-36834717

RESUMO

We investigated the role of a sirolimus-embedded silk microneedle (MN) wrap as an external vascular device for drug delivery efficacy, inhibition of neointimal hyperplasia, and vascular remodeling. Using dogs, a vein graft model was developed to interpose the carotid or femoral artery with the jugular or femoral vein. The control group contained four dogs with only interposed grafts; the intervention group contained four dogs with vein grafts in which sirolimus-embedded silk-MN wraps were applied. After 12-weeks post-implantation, 15 vein grafts in each group were explanted and analyzed. Vein grafts applied with the rhodamine B-embedded silk-MN wrap showed far higher fluorescent signals than those without the wrap. The diameter of vein grafts in the intervention group decreased or remained stable without dilatation; however, it increased in the control group. The intervention group had femoral vein grafts with a significantly lower mean neointima-to-media ratio, and had vein grafts with an intima layer showing a significantly lower collagen density ratio than the control group. In conclusion, sirolimus-embedded silk-MN wrap in a vein graft model successfully delivered the drug to the intimal layer of the vein grafts. It prevented vein graft dilatation, avoiding shear stress and decreasing wall tension, and it inhibited neointimal hyperplasia.


Assuntos
Neointima , Sirolimo , Animais , Cães , Neointima/prevenção & controle , Hiperplasia , Sirolimo/farmacologia , Artérias Carótidas , Sistemas de Liberação de Medicamentos
5.
Biosens Bioelectron ; 220: 114912, 2023 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-36413912

RESUMO

Microneedle (MN) sensing of biomarkers in interstitial fluid (ISF) can overcome the challenges of self-diagnosis of diseases by a patient, such as blood sampling, handling, and measurement analysis. However, the MN sensing technologies still suffer from poor measurement accuracy due to the small amount of target molecules present in ISF, and require multiple steps of ISF extraction, ISF isolation from MN, and measurement with additional equipment. Here, we present a swellable MN-mounted nanogap sensor that can be inserted into the skin tissue, absorb ISF rapidly, and measure biomarkers in situ by amplifying the measurement signals by redox cycling in nanogap electrodes. We demonstrate that the MN-nanogap sensor measures levodopa (LDA), medication for Parkinson disease, down to 100 nM in an aqueous solution, and 1 µM in both the skin-mimicked gelatin phantom and porcine skin.


Assuntos
Técnicas Biossensoriais , Doença de Parkinson , Suínos , Animais , Levodopa , Agulhas , Líquido Extracelular
6.
Expert Opin Drug Deliv ; 19(9): 1115-1131, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36062366

RESUMO

INTRODUCTION: Microneedles (MNs) have undergone great advances in transdermal drug delivery, and commercialized MN applications are currently available in vaccination and cosmetic products. Despite the development of MN technologies, common limitations of MN products still exist. Typical MN patches are applied to target tissues, where the substrate of an MN patch must remain until the drug is delivered, which reduces patients' compliance and hinders the applicability of the MN technique to many diseases in various tissues. MN research is ongoing to solve this issue. AREAS COVERED: Most recent MNs developed by combining various biomaterials with appropriate fabrication processes are detachable MNs (DeMNs). Because of advances in biomaterials and fabrication techniques, various DeMNs have been rapidly developed. In this review, we discuss four types of DeMN: substrate-separable, multi-layered, crack-inducing, and shell DeMN. These DeMNs deliver various therapeutic agents ranging from small- and large-molecular-weight drugs to proteins and even stem cells for regeneration therapy. Furthermore, DeMNs are applied to skin as well as non-transdermal tissues. EXPERT OPINION: It has become increasingly evident that novel MN technologies can be expected in terms of designs, fabrication methods, materials, and even possible application sites given the recent advances in DeMNs.


Assuntos
Sistemas de Liberação de Medicamentos , Agulhas , Administração Cutânea , Materiais Biocompatíveis , Sistemas de Liberação de Medicamentos/métodos , Humanos , Microinjeções , Preparações Farmacêuticas
7.
Small ; 18(21): e2107714, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35487761

RESUMO

Silk fibroin (SF) is a promising biomaterial for tendon repair, but its relatively rigid mechanical properties and low cell affinity have limited its application in regenerative medicine. Meanwhile, gelatin-based polymers have advantages in cell attachment and tissue remodeling but have insufficient mechanical strength to regenerate tough tissue such as tendons. Taking these aspects into account, in this study, gelatin methacryloyl (GelMA) is combined with SF to create a mechanically strong and bioactive nanofibrous scaffold (SG). The mechanical properties of SG nanofibers can be flexibly modulated by varying the ratio of SF and GelMA. Compared to SF nanofibers, mesenchymal stem cells (MSCs) seeded on SG fibers with optimal composition (SG7) exhibit enhanced growth, proliferation, vascular endothelial growth factor production, and tenogenic gene expression behavior. Conditioned media from MSCs cultured on SG7 scaffolds can greatly promote the migration and proliferation of tenocytes. Histological analysis and tenogenesis-related immunofluorescence staining indicate SG7 scaffolds demonstrate enhanced in vivo tendon tissue regeneration compared to other groups. Therefore, rational combinations of SF and GelMA hybrid nanofibers may help to improve therapeutic outcomes and address the challenges of tissue-engineered scaffolds for tendon regeneration.


Assuntos
Fibroínas , Células-Tronco Mesenquimais , Nanofibras , Proliferação de Células , Gelatina , Células-Tronco Mesenquimais/metabolismo , Metacrilatos , Seda , Tendões , Engenharia Tecidual , Alicerces Teciduais , Fator A de Crescimento do Endotélio Vascular/metabolismo
8.
Nanoscale ; 14(13): 5138-5146, 2022 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-35302135

RESUMO

From mechanical syringes to electric field-assisted injection devices, precise control of liquid droplet generation has been sought after, and the present state-of-the-art technologies have provided droplets ranging from nanoliter to subpicoliter volume sizes. In this study, we present a new laser-driven method to generate liquid droplets with a zeptoliter volume, breaking the fundamental limits of previous studies. We guided an infrared laser beam through a hollow optical fiber (HOF) with a ring core whose end facet was coated with single-walled carbon nanotubes. The laser light was absorbed by this nanotube film and efficiently generated a highly localized microring heat source. This evaporated the liquid inside the HOF, which rapidly recondensed into zeptoliter droplets in the surrounding air at room temperature. We spectroscopically confirmed the chemical structures of the liquid precursor maintained in the droplets by atomizing dye-dissolved glycerol. Moreover, we explain the fundamental physical principles as well as functionalities of the optical atomizer and perform a detailed characterization of the droplets. Our approach has strong prospects for nanoscale delivery of biochemical substances in minuscule zeptoliter volumes.

9.
Adv Healthc Mater ; 11(12): e2102599, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35192734

RESUMO

Intravitreal injection (IVI) is a common technology which is used to treat ophthalmic diseases inside eyeballs by delivering various drugs into the vitreous cavity using hypodermic needles. However, in some cases, there are possible side effects such as ocular tissue damage due to repeated injection or eyeball infection through the hole created during the needle retraction process. The best scenario of IVI is a one-time injection of drugs without needle retraction, keeping the system of the eyeball closed. Microneedles (MNs) have been applied to ocular tissues over 10 years, and no serious side effects on ocular tissue due to MN injection have been reported. Therefore, a self-plugging MN (SPM) is developed to perform intraocular drug delivery and to seal the scleral puncture simultaneously. The SPMs are fabricated by a thermal drawing process and then coated with a polymeric carrier of drugs and a hydrogel-based scleral plugging component. Each coated functional layer is characterized and demonstrated by in vitro and ex vivo experiments. Finally, in vivo tests using a porcine model confirms prompt sealing of SPM and sustained intraocular drug delivery.


Assuntos
Sistemas de Liberação de Medicamentos , Agulhas , Administração Cutânea , Animais , Excipientes , Olho , Hidrogéis/farmacologia , Microinjeções , Suínos
10.
J Control Release ; 340: 125-135, 2021 12 10.
Artigo em Inglês | MEDLINE | ID: mdl-34688718

RESUMO

Various perivascular drug delivery techniques have been demonstrated for localized post-treatment of intimal hyperplasia: a vascular inflammatory response caused by endothelial damages. Although most perivascular devices have focused on controlling the delivery duration of anti-proliferation drug, the confined and unidirectional delivery of the drug to the target tissue has become increasingly important. In addition, careful attention should also be paid to the luminal stability and the adequate exchange of vascular protein or cell between the blood vessel and extravascular tissue to avoid any side effect from the long-term application of any perivascular device. Here, a highly flexible and porous silk fibroin microneedle wrap (Silk MN wrap) is proposed to directly inject antiproliferative drug to the anastomosis sites while ensuring sufficient vascular exchanges. Drug-embedded silk MNs were transfer-molded on a highly flexible and porous silk wrap. The enhanced cell compatibility, molecular permeability, and flexibility of silk MN wrap guaranteed the structural integrity of blood vessels. Silk wrap successfully supported the silk MNs and induced multiple MN penetration to the target tissue. Over 28 days, silk MN wrap significantly inhibited intimal hyperplasia with a 62.1% reduction in neointimal formation.


Assuntos
Sistemas de Liberação de Medicamentos , Fibroínas , Agulhas , Porosidade
11.
Sci Adv ; 7(20)2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33980487

RESUMO

The harvesting of photosynthetic electrons (PEs) directly from photosynthetic complexes has been demonstrated over the past decade. However, their limited efficiency and stability have hampered further practical development. For example, despite its importance, the interfacial electron transfer between the photosynthetic apparatus and the electrode has received little attention. In this study, we modified electrodes with RuO2 nanosheets to enhance the extraction of PEs from thylakoids, and the PE transfer was promoted by proton adsorption and surface polarity characteristics. The adsorbed protons maintained the potential of an electrode more positive, and the surface polarity enhanced thylakoid attachment to the electrode in addition to promoting ensemble docking between the redox species and the electrode. The RuO2 bioanode exhibited a five times larger current density and a four times larger power density than the Au bioanode. Last, the electric calculators were successfully powered by photosynthetic energy using a RuO2 bioanode.

12.
Adv Healthc Mater ; 10(11): e2002287, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33930253

RESUMO

Infectious keratitis is mainly treated with topical antibiotics. To achieve and maintain the required therapeutic concentration in the cornea where the tear fluid continuously rinses the surface, the antibiotics must be frequently applied, even while the patient is sleeping, and oral medication is sometimes required. However, the inevitably poor compliance and avascular nature of the cornea decrease drug bioavailability. In this study, a single microneedle (MN) is injected into the cornea to substitute for the repeated application of eyedrops in the treatment of infectious keratitis. After comparing the mechanical integrity and drug release profiles of three different drug-tips, the drug-tip with the "high" drug concentration that releases 12.5 ng drug within 3 days is applied to a cornea to evaluate the transferability and in vivo drug release. In the treatment of infectious keratitis with repeated application of eyedrops for six consecutive days, a single MN injection is substituted for the initial 3 days of eyedrop applications. The progression remains similarly attenuated after 3 days without eyedrops, and comparable efficacy is achieved on day 6 when combined with delayed eyedrop treatment from day 3. Thus, the single administration of a biodegradable MN can substitute for the repeated application of eyedrops in the treatment of infectious keratitis.


Assuntos
Ceratite , Administração Tópica , Córnea , Humanos , Ceratite/tratamento farmacológico , Agulhas , Soluções Oftálmicas/uso terapêutico , Lágrimas
13.
Adv Mater ; 33(47): e2005919, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33236450

RESUMO

Harvesting solar energy in the form of electricity from the photosynthesis of plants, algal cells, and bacteria has been researched as the most environment-friendly renewable energy technology in the last decade. The primary challenge has been the engineering of electrochemical interfacing with photosynthetic apparatuses, organelles, or whole cells. However, with the aid of low-dimensional nanomaterials, there have been many advances, including enhanced photon absorption, increased generation of photosynthetic electrons (PEs), and more efficient transfer of PEs to electrodes. These advances have demonstrated the possibility for the technology to advance to a new level. In this article, the fundamentals of photosynthesis are introduced. How PE harvesting systems have improved concerning solar energy absorption, PE production, and PE collection by electrodes is discussed. The review focuses on how different kinds of nanomaterials are applied and function in interfacing with photosynthetic materials for enhanced PE harvesting. Finally, the review analyzes how the performance of PE harvesting and stand-alone systems have evolved so far and its future prospects.


Assuntos
Energia Renovável
14.
ACS Appl Mater Interfaces ; 12(49): 54683-54693, 2020 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-33226773

RESUMO

Direct harvesting of electricity from photosynthesis is highly desired as an eco-friendly and sustainable energy harvesting technology. Photosynthetic apparatuses isolated from plants, such as thylakoid membranes (TMs), are deposited on an electrode by which photosynthetic electrons (PEs) are collected from water splitting. To enhance PE collection efficiency, it is critical to increase the electrochemical interfaces between TMs and the electrode. Considering the size of TMs to be around a few hundred nanometer, we hypothesize that an array of micropillar-shaped (MP) electrode can maximize the TM/electrode interface area. Thus, we developed MP electrodes with different heights and investigated the electrospraying of TM-alginate mixtures to fill the gaps between MPs uniformly and conformally. The uniformity of the TM-alginate film and the interaction between the TM and the MP electrode were evaluated to understand how the MP heights and film quality influenced the magnitude of the PE currents. PE currents increased up to 2.4 times for an MP electrode with an A/R of 1.8 compared to a flat electrode, indicating increased direct contact interface between TMs and the electrode. Furthermore, to demonstrate the scalability of this approach, an array of replicated SU-8 MP electrodes was prepared and PE currents of up to 3.2 µA were monitored without a mediator under 68 mW/cm2. Finally, the PE current harvesting was sustained for 14 days without decay, demonstrating the long-term stability of the TM-alginate biophotoanodes.

15.
Cancers (Basel) ; 12(11)2020 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-33114476

RESUMO

Recently, cancer immunotherapy has received attention as a viable solution for the treatment of refractory tumors. However, it still has clinical limitations in its treatment efficacy due to inter-patient tumor heterogeneity and immunosuppressive tumor microenvironment (TME). In this study, we demonstrated the triggering of anti-cancer immune responses by a combination of irreversible electroporation (IRE) and a stimulator of interferon genes (STING) agonist. Optimal electrical conditions inducing damage-associated molecular patterns (DAMPs) by immunogenic cell death (ICD) were determined through in vitro 2D and 3D cell experiments. In the in vivo syngeneic lung cancer model, the combination of IRE and STING agonists demonstrated significant tumor growth inhibition. We believe that the combination strategy of IRE and STING agonists has potential for effective cancer immunotherapy.

16.
Adv Biosyst ; 4(7): e2000040, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32462817

RESUMO

Genetically encoded photoelectric silk that can convert photons to electrons (light to electricity) over a wide visible range in a self-power mode is reported. As silk is a versatile host material with electrical conductivity, biocompatibility, and processability, a photoelectric protein is genetically fused with silk by silkworm transgenesis. Specifically, mKate2, which is conventionally known as a far-red fluorescent protein, is used as a photoelectric protein. Characterization of the electrochemical and optical properties of mKate2 silk allows designing a photoelectric measurement system. A series of in situ photocurrent experiments support the sensitive and stable performance of photoelectric conversion. In addition, as a plasmonic nanomaterial with a broad spectral resonance, titanium nitride (TiN) nanoparticles are biologically hybridized into the silk glands, taking full advantage of the silkworms' open circulatory system as well as the absorption band of mKate2 silk. This biological hybridization via direct feeding of TiN nanoparticles further enhances the overall photoelectric conversion ability of mKate2 silk. It is envisioned that the biologically derived photoelectric protein, its ecofriendly scalable production by transgenic silkworms, and the bioassisted plasmonic hybridization can potentially broaden the biomaterial choices for developing next-generation biosensing, retina prosthesis, and neurostimulation applications.


Assuntos
Animais Geneticamente Modificados , Bombyx/química , Proteínas Luminescentes/química , Nanopartículas/química , Seda/química , Titânio/química , Animais , Bombyx/genética , Bombyx/metabolismo , Proteínas Luminescentes/biossíntese , Proteínas Luminescentes/genética , Seda/biossíntese , Seda/genética , Proteína Vermelha Fluorescente
17.
J Control Release ; 321: 174-183, 2020 05 10.
Artigo em Inglês | MEDLINE | ID: mdl-32035908

RESUMO

High rates of restenosis and neointimal formation have driven increasing interest in the application of drug eluting balloons (DEB) as counteractive measures for intraluminal drug delivery. The use of DEBs eliminates the need for stents so that serious side effects including in-stent restenosis and stent thrombosis can be avoided and long-term medication of anti-platelet agent is not needed. Despite their benefits, DEBs have poor drug delivery efficiency due to short balloon inflation times (30-60 s) that limit the passive drug diffusion from the balloon surface to the luminal lesion. To increase drug delivery efficiency, a microneedle DEB (MNDEB) was developed by a conformal transfer molding process using a thin polydimethylsiloxane mold bearing a negative array of MNs of 200 µm in height. A MN array composed of UV curable resin was formed onto the surface of DEB, and drugs were coated onto the structure. The mechanical properties of the MN array were investigated and MN penetration into luminal vasculature was confirmed in vivo. An increase in drug delivery efficiency compared to a standard DEB was demonstrated in an in vivo test in a rabbit aorta. Finally, the superior therapeutic efficacy of MNDEBs was evaluated using an atherosclerosis rabbit model.


Assuntos
Angioplastia Coronária com Balão , Fármacos Cardiovasculares , Stents Farmacológicos , Preparações Farmacêuticas , Animais , Materiais Revestidos Biocompatíveis , Paclitaxel , Desenho de Prótese , Coelhos , Stents , Resultado do Tratamento
18.
Adv Drug Deliv Rev ; 165-166: 41-59, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31837356

RESUMO

Microneedles (MNs) have been used to deliver drugs for over two decades. These platforms have been proven to increase transdermal drug delivery efficiency dramatically by penetrating restrictive tissue barriers in a minimally invasive manner. While much of the early development of MNs focused on transdermal drug delivery, this technology can be applied to a variety of other non-transdermal biomedical applications. Several variations, such as multi-layer or hollow MNs, have been developed to cater to the needs of specific applications. The heterogeneity in the design of MNs has demanded similar variety in their fabrication methods; the most common methods include micromolding and drawing lithography. Numerous materials have been explored for MN fabrication which range from biocompatible ceramics and metals to natural and synthetic biodegradable polymers. Recent advances in MN engineering have diversified MNs to include unique shapes, materials, and mechanical properties that can be tailored for organ-specific applications. In this review, we discuss the design and creation of modern MNs that aim to surpass the biological barriers of non-transdermal drug delivery in ocular, vascular, oral, and mucosal tissue.


Assuntos
Sistemas de Liberação de Medicamentos/métodos , Microinjeções/instrumentação , Microinjeções/métodos , Administração Tópica , Transporte Biológico , Desenho de Equipamento , Humanos , Microtecnologia/métodos , Polímeros , Próteses e Implantes
19.
Pharmaceutics ; 11(3)2019 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-30813634

RESUMO

Microneedles (MNs) have been extensively developed over the last two decades, and highly efficient drug delivery was demonstrated with their minimal invasiveness via a transdermal route. Recently, MNs have not only been applied to the skin but also to other tissues such as blood vessels, scleral tissue, and corneal tissue. In addition, the objective of the MN application has been diversified, ranging from drug delivery to wound closure and biosensing. However, since most MN fabrication methods are expensive and time-consuming, they are inappropriate to prototype MNs for various tissues that have different and complex anatomies. Although several drawing-based techniques have been introduced for rapid MN production, they fabricated MNs with limited shapes, such as thin MNs with wide bases. In this study, we propose a three-step thermal drawing for rapid, prototyping MNs that can have a variety of shapes and can be fabricated on curved surfaces. Based on the temperature control of polymer bridge formation during thermal drawing, the body profile and aspect ratios of MNs were conveniently controlled, and the effect of temperature control on the body profile of MNs was explained. Thermally drawn MNs with different shapes were fabricated both on flat and curved surfaces, and they were characterized in terms of their mechanical properties and insertion into vascular tissue to find an optimal shape for vascular tissue insertion.

20.
Annu Int Conf IEEE Eng Med Biol Soc ; 2018: 3338-3341, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30441103

RESUMO

This paper presents a 0.9m long capacitive force sensor for a catheter integration, which measures a contact force to inner vessel wall or organs with a resolution of 0.5gf. The force sensor is implemented with a thin flexible printed circuit board (FPCB) encapsulated by a force sensitive medium, multilayer polydimethylsiloxane (PDMS). The parasitic capacitance $( \mathrm {C}_{P})$ inherent in long catheters significantly degrades the sensing accuracy of capacitive force sensors. To account for this, this work proposes a sensor interface with $\mathrm {C}_{P}$ canceller. By removing the 348pF (91.5%) of $\mathrm {C}_{\mathrm{P}}$with the $\mathrm {C}_{\mathrm{P}}$ canceller, the capacitive force sensor achieves a capacitance resolution of 16aF equivalent to a force error of 0.5gf, which is a $10 \times $ improvement compared to the conventional sensor interface. The proposed force sensor offers great potential for real-time force monitoring of cardiovascular surgery.


Assuntos
Catéteres , Capacitância Elétrica , Desenho de Equipamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...